The iterated horizontal and vertical K values in the unit [m/s] can be saved directly to the KWER or KWEV attribute via Attributes
Import model data/results data....
The FE calculation also provides the following results.
Potential heads at all nodes,
Depth to the groundwater table at all nodes, provided that the surface elevation is defined in the model file,
Mass flow rates (inflow or outflow rates) for all nodes with a specified potential,
Leakage rates for nodes and elements, provided that the leakage coefficients (LERA, LEKN, LEEL) and reference water level for watercourses were specified in the model data, and
Mass balance of the total rate of all inflows and outflows. These are placed in relation to the total rate of the mass flow rates. The sum of all entered and calculated rates must be close to zero. In addition, all inflows (positive) are compared with outflows (negative) and, if specified in the mesh file, the balance areas summarised via the data types BILK and BILE are balanced.